SIGINT is sent when you press Ctrl+C. SIGTERM is sent in just about every other situation - basically when the system wants the program to end. For instance when systemd wants to stop the service or the default signal with programs like killpkillhtop etc. You should catch both of these signals.
When I run the script myself and kill it, it gets the signal and acts correctly. Only when I poweroff the system, this doesn’t work.
SIGINT is sent when you press Ctrl+C. SIGTERM is sent in just about every other situation - basically when the system wants the program to end. For instance when systemd wants to stop the service or the default signal with programs like
kill
pkill
htop
etc. You should catch both of these signals.I did try to catch all of these signals:
| "SIGABRT" | "SIGALRM" | "SIGBUS" | "SIGCHLD" | "SIGCONT" | "SIGFPE" | "SIGHUP" | "SIGILL" | "SIGINT" | "SIGIO" | "SIGIOT" | "SIGKILL" | "SIGPIPE" | "SIGPOLL" | "SIGPROF" | "SIGPWR" | "SIGQUIT" | "SIGSEGV" | "SIGSTKFLT" | "SIGSTOP" | "SIGSYS" | "SIGTERM" | "SIGTRAP" | "SIGTSTP" | "SIGTTIN" | "SIGTTOU" | "SIGUNUSED" | "SIGURG" | "SIGUSR1" | "SIGUSR2" | "SIGVTALRM" | "SIGWINCH" | "SIGXCPU" | "SIGXFSZ" | "SIGBREAK" | "SIGLOST" | "SIGINFO";
Good luck trapping the SIGKILL signal